{"id":2395,"date":"2026-11-28T09:01:05","date_gmt":"2026-11-28T09:01:05","guid":{"rendered":"https:\/\/www.aussiebatt.com\/blog\/?p=2395"},"modified":"2026-11-28T09:01:06","modified_gmt":"2026-11-28T09:01:06","slug":"keep-power-tool-batteries-alive-complete-maintenance-safety-troubleshooting-guide","status":"publish","type":"post","link":"https:\/\/www.aussiebatt.com\/blog\/keep-power-tool-batteries-alive-complete-maintenance-safety-troubleshooting-guide\/","title":{"rendered":"Keep Power Tool Batteries Alive: Complete Maintenance, Safety, Troubleshooting Guide"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">A $127 cordless drill battery dies after six months is not a manufacturing defect \u2014 it is usually operator error. Power tool lithium batteries are engineered to deliver 500\u20131,500 charge cycles, but real-world jobsite conditions \u2014 heat, dust, impact, improper charging habits, and storage at full charge in a hot van \u2014 can cut that lifespan in half or worse. Almost all premature battery failures are preventable with simple, consistent maintenance habits that take seconds per day.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Following complete guide covers 3 pillars of <a href=\"https:\/\/www.aussiebatt.com\/australia-power-tool-batteries-supplier.html\">power tool battery management<\/a>: daily maintenance practices that extend cycle life by 30\u201350%, critical safety rules that prevent the lithium battery fires that make headlines, and a systematic troubleshooting flowchart for diagnosing the four most common failure modes \u2014 battery not charging, battery overheating, abnormally short runtime, and battery not recognized by the tool.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why Cordless Tool Batteries Die Early: The Four Silent Killers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before we discuss solutions, understand what you are fighting against. These four factors account for over 80% of premature power tool battery failures in professional use:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">1. Heat \u2014 The Number One Battery Killer<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Every 10\u00b0C increase in operating temperature above 25\u00b0C roughly halves the rate of chemical degradation inside lithium-ion cells. A battery left in a closed work van on a summer afternoon can reach 60\u201370\u00b0C \u2014 equivalent to aging the battery by 3\u20136 months in a single afternoon. Similarly, immediately placing a hot battery (fresh off a high-drain tool) onto a fast charger pushes cell temperature above 45\u00b0C during the charge cycle, accelerating degradation of the electrolyte and the solid electrolyte interface (SEI) layer on the anode.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The fix:<\/strong> Let batteries cool for 15\u201320 minutes after heavy use before charging. Store batteries in a climate-controlled environment (below 30\u00b0C) whenever possible. If working in extreme heat is unavoidable, rotate through 3\u20134 batteries rather than running one battery continuously, giving each pack time to cool between uses.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">2. Deep Discharge Below 2.5V Per Cell<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Running a lithium-ion battery until the tool completely stops \u2014 often called &#8220;draining it dead&#8221; \u2014 forces one or more cell groups below 2.5V. At this voltage, copper from the negative current collector begins to dissolve into the electrolyte. When the battery is subsequently recharged, this dissolved copper plates onto the anode as metallic dendrites \u2014 microscopic needle-like structures that can penetrate the separator and create internal short circuits. This damage is cumulative and irreversible: each deep-discharge event permanently reduces capacity and increases internal resistance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The fix:<\/strong> Swap batteries when the tool noticeably slows down or the battery fuel gauge shows 1 bar remaining \u2014 do not wait until the tool stops completely. Most power tool BMS units will cut off discharge at 2.5\u20132.7V per cell, but it is better to never reach this threshold in normal use.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">3. Storage at 100% Charge<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Lithium-ion cells degrade fastest when stored at full charge. At 4.2V per cell (100% SOC), the cathode is in a highly oxidized, chemically reactive state that drives parasitic reactions with the electrolyte, consuming active lithium and increasing internal resistance. A battery stored at 100% SOC and 25\u00b0C loses approximately 3\u20135% of its capacity per year from calendar aging alone \u2014 at 40\u00b0C, this accelerates to 10\u201315% per year.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The fix:<\/strong> If a battery will not be used for more than one week, discharge it to 40\u201360% SOC (approximately 3.7V per cell, or 2\u20133 bars on a 4-bar LED fuel gauge) before storage. This is the chemically most stable state, minimizing calendar aging. The ideal storage temperature is 10\u201325\u00b0C. Never store batteries at 100% charge for extended periods \u2014 a battery that sits fully charged on a shelf for six months will have measurably less capacity than one stored at 50% SOC.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">4. Physical Abuse \u2014 Drops, Impacts, and Vibration<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Power tool batteries live a hard life. They get dropped from ladders, knocked off workbenches, vibrated for hours by recip saws and hammer drills, and exposed to rain, concrete dust, and metal shavings. Each drop can fracture internal spot welds, crack the BMS PCB, or dent cell casings \u2014 any of which can cause intermittent connections, increased internal resistance, or internal short circuits.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The fix:<\/strong> Inspect batteries visually at the start of each workday: check for housing cracks, terminal corrosion, and any sign of swelling or deformation. A battery with a cracked housing should be retired immediately \u2014 the crack allows moisture and conductive dust to reach the cells and BMS. Use rubber boot accessories (available for most major battery platforms) to absorb impact. And invest in batteries with glass-filled nylon housings and rubber overmold \u2014 the additional durability pays for itself in reduced replacement frequency.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Troubleshooting: Diagnosing the Four Most Common Power Tool Battery Failures<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Problem 1: Battery Not Charging \u2014 Charger Shows Error or No Light<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 1: Check battery voltage with a multimeter.<\/strong> Set the multimeter to DC voltage and probe the battery terminals. An <a href=\"https:\/\/www.aussiebatt.com\/makita-pa18-drill-battery.html\">18V Makita PA8 battery replacement<\/a> should read between 15V (fully discharged) and 21V (fully charged). If the reading is 0V, the BMS has likely entered protection mode due to severe over-discharge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 2: Attempt BMS reset.<\/strong> Some BMS units can be reset by applying a brief charge voltage directly to the pack terminals (bypassing the BMS) \u2014 but this should only be attempted by someone with electronics experience, as incorrect polarity or excessive voltage can cause fires. An alternative: place the battery on the charger for 30 seconds, remove it, wait 10 seconds, and reinsert. Some chargers send a brief &#8220;wake-up&#8221; pulse that can reset a tripped BMS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 3: Check individual cell group voltages.<\/strong> If you can access the balance connector, measure each cell group voltage. If one group is significantly lower than the others (&gt;0.5V difference), the pack has a dead or severely imbalanced cell. This battery cannot be safely recovered and should be recycled.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 4: Check charger functionality.<\/strong> Test the charger with a known-good battery. If the charger works with another battery but not with the problematic one, the issue is in the battery. If the charger does not work with any battery, replace the charger.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 5: Clean the terminals.<\/strong> Dirty or oxidized battery terminals can prevent the charger from detecting the battery and initiating charge. Clean the terminals with isopropyl alcohol and a cotton swab. Check for bent or recessed pins \u2014 a common issue with batteries that have been dropped.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Problem 2: Battery Overheating During Use or Charging<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">A power tool battery that becomes uncomfortably hot to hold (above 50\u00b0C) during normal use indicates one of three problems: cells with high internal resistance, poor internal connections creating hot spots, or a tool that draws more current than the battery is rated for.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Diagnosis:<\/strong> Measure the battery&#8217;s internal resistance (see testing section below). If IR is more than 50% above the expected value for that cell model, the cells are aging and should be replaced. If IR is normal, the problem may be a high-resistance weld or connector \u2014 these create localized hot spots that the BMS temperature sensor (mounted on the PCB, not on every cell) may not detect until the pack is already overheating.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Immediate action:<\/strong> Stop using an overheating battery. Let it cool completely in a fire-safe location (concrete floor, metal container, outdoors away from flammable materials). A battery that has overheated once is at increased risk of subsequent overheating \u2014 monitor it closely in future use.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Problem 3: Abnormally Short Runtime \u2014 Battery Dies After a Few Minutes<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">If a battery that previously powered your tool for 30+ minutes now dies after 5\u201310 minutes, one of three things has happened: the cells have lost capacity through aging, one cell group is imbalanced and triggering early low-voltage cutoff, or the BMS has developed a fault that triggers premature protection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 1: Perform a capacity test.<\/strong> Fully charge the battery, connect a known constant load (e.g., a 12V 50W halogen bulb for an 18V pack, which draws approximately 3A), and time how long the battery runs before the BMS cutoff. Multiply current by time to calculate actual capacity. Compare to rated capacity \u2014 if it is below 70%, the battery is at end of life.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 2: Check cell balance.<\/strong> Measure individual cell group voltages at full charge. All groups should be within 0.05V of each other. If one group is 0.2V or more lower than the others, the pack is imbalanced and that weak cell group triggers early cutoff. A severely imbalanced pack needs cell replacement or recycling.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 3: Rule out the tool.<\/strong> Test the battery in a different tool that draws similar current. If runtime is normal in the other tool, the original tool may have a binding bearing, worn brushes (if brushed motor), or internal electrical fault that increases current draw. A tool that draws 20% more current than normal will reduce battery runtime by 20% \u2014 appearing as a battery problem when the tool is the root cause.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Problem 4: Battery Not Recognized by Tool \u2014 Tool Refuses to Operate<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">This is almost always a communication issue between the battery BMS and the tool&#8217;s controller. Each major brand uses a proprietary protocol to verify that a &#8220;genuine&#8221; battery is connected. If the battery&#8217;s identification resistor, thermistor value, or digital ID signal does not match what the tool expects, the tool will not power on \u2014 even if the battery is fully charged and electrically perfect.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 1: Clean all terminals thoroughly.<\/strong> The third small terminal (separate from the positive and negative power terminals) is the communication pin. If it is dirty or oxidized, the tool cannot read the battery ID. Clean with isopropyl alcohol.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 2: Test the battery in a different tool of the same brand (if available).<\/strong> If it works in one tool but not another, the problem is with the tool, not the battery.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 3: Check the thermistor.<\/strong> Many brands use a 10k\u03a9 NTC thermistor between the communication pin and negative. If this thermistor has failed (open circuit or short), the tool will detect an implausible temperature reading and refuse to operate. A multimeter resistance reading between the ID pin and negative should show approximately 8\u201312k\u03a9 at room temperature.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Lithium Battery Fire Safety for Construction Sites<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lithium battery fires on construction sites are rare but devastating when they occur. A single punctured or severely overheated power tool battery can ignite within seconds and reach temperatures exceeding 600\u00b0C \u2014 enough to ignite surrounding materials and create a structure fire. These safety rules are not optional for any professional operation:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Never charge batteries on or near flammable materials.<\/strong> The charging station should be on a concrete floor, metal shelf, or purpose-built metal charging cabinet \u2014 not on a wooden workbench, cardboard box, or stack of lumber. Maintain at least 1 meter clearance from combustible materials in all directions.<\/li>\n\n\n\n<li><strong>Never leave charging batteries unattended overnight.<\/strong> The vast majority of serious lithium battery fire incidents occur when batteries are left charging unattended \u2014 overnight in a workshop, after hours on a jobsite, or in a vehicle. If a fire starts with no one present to respond, the result is total loss of the structure. Charge only during working hours when someone is present and awake.<\/li>\n\n\n\n<li><strong>Use only the correct charger for your battery platform.<\/strong> A Makita charger on a Dewalt battery or vice versa will not physically connect, but universal &#8220;multi-brand&#8221; chargers sold online often apply incorrect charge voltages and currents. Using a charger not specifically designed for your battery chemistry, voltage, and cell configuration is the single most common cause of charging-related battery fires.<\/li>\n\n\n\n<li><strong>Inspect batteries before each use.<\/strong> Look for: housing cracks or deformation, terminal corrosion or melting, swollen or bulging case (a sign of internal gas generation \u2014 this battery is extremely dangerous and must be disposed of immediately), and any odor of solvent or sweet chemical smell (electrolyte leakage). Any battery showing these signs must be removed from service and properly recycled \u2014 do not attempt to charge or use it.<\/li>\n\n\n\n<li><strong>Have a Class D fire extinguisher accessible.<\/strong> Standard ABC dry chemical extinguishers are ineffective against lithium battery fires \u2014 the battery provides its own oxygen, so smothering does not work. A Class D extinguisher (for combustible metals) or a lithium-battery-specific extinguisher (such as the Li-Fire or AVD types) is the correct equipment. At minimum, keep a bucket of dry sand nearby to smother a small battery fire.<\/li>\n\n\n\n<li><strong>Transport batteries safely.<\/strong> When transporting multiple batteries between jobsites, each battery should be in its own compartment or have its terminals covered with electrical tape to prevent accidental short circuits. Loose batteries rattling around in a tool bag with metal tools, screws, and nails are a short-circuit waiting to happen. Use purpose-built battery transport cases or dedicated battery storage bags.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">How to Test Your Power Tool Battery Health with a Multimeter<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">You do not need expensive battery analysis equipment to perform a basic health assessment. A digital multimeter ($20\u201340) is sufficient for the two most informative tests:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Test 1: Resting Voltage Check<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Fully charge the battery, remove it from the charger, and let it rest for 1 hour (this allows the voltage to stabilize). Measure the voltage at the battery terminals. For an 18V (5S) pack: a healthy fully charged pack reads approximately 20.5\u201321.0V. If it reads below 20.0V after a full charge, either one cell group is not reaching full charge (BMS cuts off charging early due to that group hitting 4.2V first) or the cells have significant capacity loss.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Test 2: Internal Resistance Estimation<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Internal resistance (IR) is the single best indicator of battery health. As cells age, IR increases, which causes more voltage sag under load, more heating, and less usable capacity. To estimate:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Measure resting voltage V1 (no load).<\/li>\n\n\n\n<li>Apply a known load (e.g., a 12V 50W halogen bulb drawing approximately 3A for an 18V pack) and measure voltage V2 under load.<\/li>\n\n\n\n<li>Measure the actual load current I with a clamp meter or by placing the multimeter in series.<\/li>\n\n\n\n<li>Calculate IR: IR = (V1 \u2212 V2) \u00f7 I.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">For a 5S2P pack of Samsung 25R cells (13m\u03a9 per cell): expected pack IR = 5 \u00d7 13 \u00f7 2 = 32.5m\u03a9. A new, healthy pack should measure 30\u201340m\u03a9. Above 60m\u03a9, the pack has significant aging. Above 80m\u03a9, the pack is near end of life and will overheat under heavy use.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Test 3: Cycle Count Estimation<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">If your battery has Bluetooth connectivity, the app typically displays an exact cycle count. Without that, estimate cycles based on age and usage pattern: daily professional use averages 250\u2013350 cycles per year, weekly DIY use averages 30\u201350 cycles per year. Compare against the expected cycle life for your cell chemistry: premium NMC cells (Samsung, LG, Molicel) deliver 800\u20131,200 cycles to 70% capacity when properly maintained. Budget cells from unknown manufacturers may deliver only 300\u2013500 cycles.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Battery Storage Best Practices<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Storage Duration<\/td><td>Recommended SOC<\/td><td>Temperature<\/td><td>Additional Notes<\/td><\/tr><tr><td>1\u20137 days (between jobs)<\/td><td>Any level OK<\/td><td>10\u201330\u00b0C<\/td><td>Charge to full before next use<\/td><\/tr><tr><td>1\u20134 weeks<\/td><td>40\u201360% (2 bars on LED gauge)<\/td><td>10\u201325\u00b0C<\/td><td>Remove from tool; store in case<\/td><\/tr><tr><td>1\u20136 months (off-season)<\/td><td>40\u201350% (1\u20132 bars on LED gauge)<\/td><td>10\u201325\u00b0C<\/td><td>Check voltage every 3 months; recharge to 50% if below 20%<\/td><\/tr><tr><td>6+ months (long-term)<\/td><td>40\u201350% (1\u20132 bars on LED gauge)<\/td><td>10\u201320\u00b0C<\/td><td>Disconnect BMS if possible to eliminate standby drain; check every 3 months<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Safe Disposal and Recycling of Power Tool Batteries<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When a power tool battery reaches end of life \u2014 defined as capacity below 70% of original rating, physical swelling, or inability to hold a charge \u2014 it must be recycled, not thrown in the trash. Landfilling lithium batteries is illegal in most jurisdictions and creates serious fire and environmental hazards.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>How to prepare a battery for recycling:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Discharge the battery as much as possible (use it in a tool until the tool slows down).<\/li>\n\n\n\n<li>Cover both positive and negative terminals completely with electrical tape to prevent short circuits during transport.<\/li>\n\n\n\n<li>Place each battery in its own plastic bag or wrap individually \u2014 do not allow multiple bare batteries to contact each other in a box.<\/li>\n\n\n\n<li>Drop off at an authorized collection point: Home Depot, Lowe&#8217;s, Best Buy, and Call2Recycle locations throughout North America accept power tool batteries for free recycling. In the EU and UK, most hardware stores and supermarkets have battery recycling bins.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>For fleet operators and businesses:<\/strong> ShenYe offers bulk battery recycling coordination for clients with 50+ end-of-life batteries. Contact our team to arrange collection and certified recycling documentation for your environmental compliance records.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Summary: The Daily Battery Maintenance Checklist<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Print this and post it near your charging station:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Visual check:<\/strong> Look for cracks, swelling, terminal damage, and debris on terminals.<\/li>\n\n\n\n<li><strong>Cool down:<\/strong> Let hot batteries rest 15\u201320 minutes before charging.<\/li>\n\n\n\n<li><strong>Swap early:<\/strong> Change batteries when the tool slows down \u2014 do not run to complete cutoff.<\/li>\n\n\n\n<li><strong>Clean terminals:<\/strong> Wipe terminals with a dry cloth if visibly dirty or oxidized.<\/li>\n\n\n\n<li><strong>Store right:<\/strong> Batteries not used for >1 week \u2192 discharge to 40\u201360% first.<\/li>\n\n\n\n<li><strong>Charge safely:<\/strong> On non-flammable surface, during working hours, with correct charger.<\/li>\n\n\n\n<li><strong>Retire damaged:<\/strong> Any cracked, swollen, or leaking battery \u2192 tape terminals \u2192 recycle immediately.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">For professional power tool users and fleet operators, ShenYe provides replacement batteries for all major platforms with full safety certification, quality cell sourcing documentation, and bulk pricing. <a href=\"\/products\">Browse our power tool battery product line<\/a> or contact our quality team for safety data sheets, test reports, or battery recycling coordination.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A $127 cordless drill battery dies after six months is not a manufacturing defect \u2014 it &hellip; <a title=\"Keep Power Tool Batteries Alive: Complete Maintenance, Safety, Troubleshooting Guide\" class=\"hm-read-more\" href=\"https:\/\/www.aussiebatt.com\/blog\/keep-power-tool-batteries-alive-complete-maintenance-safety-troubleshooting-guide\/\"><span class=\"screen-reader-text\">Keep Power Tool Batteries Alive: Complete Maintenance, Safety, Troubleshooting Guide<\/span>Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2395","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/posts\/2395","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/comments?post=2395"}],"version-history":[{"count":1,"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/posts\/2395\/revisions"}],"predecessor-version":[{"id":2396,"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/posts\/2395\/revisions\/2396"}],"wp:attachment":[{"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/media?parent=2395"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/categories?post=2395"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aussiebatt.com\/blog\/wp-json\/wp\/v2\/tags?post=2395"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}